Flow Control

1020CZ125

Brooks Instrument GT1020 Variable-Area Flowmeter

About this part

Brooks Instrument 1020CZ125 identifies a configured GT1020 industrial variable-area flowmeter for visual gas or liquid flow measurement. The GT1020 uses a tapered borosilicate-glass metering tube and float within a protective housing. A documented unit bearing this identifier has horizontal 1/2-inch ANSI Class 150 flanged connections, a percent-of-maximum scale, and an alarm module; these are retained as observed configuration details because Brooks’ current GT1000 literature does not fully decode the compact legacy suffix CZ125

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument GT1000 Series
Part number1020CZ125
Product familyConfiguration-specific
Device typeFlowmeter
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Product familyGT1000 Series
Model familyGT1020
Measurement principleVariable area; a float rises within a vertically installed tapered glass tube until fluid and gravitational forces reach equilibrium
GT1000 family performance
Measured mediaGas or liquid
Standard flow accuracy±2% of full scale; Class 2.5 according to VDI/VDE
Optional flow accuracy±1% of full scale; Class 1.6 according to VDI/VDE
Repeatability≤0.5% of full scale
GT1000 family environmental limits
Ambient temperature33 to 125°F (1 to 52°C)
Metered-fluid temperature33 to 250°F (1 to 121°C)
GT1000 family construction
Metering tubeBorosilicate glass
WindowPolycarbonate with ultraviolet inhibitor
HousingEpoxy-painted cast aluminum
End-fitting optionsBrass or 316/316L stainless steel
Seal optionsViton fluoroelastomer, Buna-N, Kalrez perfluoroelastomer, or EPDM; Kalrez and EPDM are limited to stainless-steel-body configurations
GT1000 family connections
Connection optionsNPT female, Rc/BSP threaded, or ANSI B16.5 Class 150 raised-face flange
Connection orientationHorizontal or vertical inlet and outlet arrangements, according to base model
GT1000 family scales
Scale constructionSingle or dual detachable aluminum plate
Nominal scale lengths127, 200, or 250 mm
Scale formatsDirect-reading engineering units, millimeters, or percent of maximum flow with factor tag
GT1000 family options
Flow alarmsOne or two adjustable alarm points; inductive sensors are used for meter sizes 2 and 6, while reed-switch alarms are offered for sizes 7 through 13

Identifier interpretation

The base model can be related to Brooks’ published GT1020 configuration, but the compact legacy suffix must remain intact unless the original order record or nameplate data are available.

1020/GT1020 base arrangementHorizontal inlet and horizontal outlet
Current published C designatorSize 2 with R-2-127-DT tube in the later 1020N model-code system
Legacy suffix boundaryThe 2018 GT1000 code table does not provide a one-to-one decode for the compact CZ125 suffix. Tube, float, seals, calibration fluid, range, and accuracy must therefore be verified from the instrument nameplate, tube marking, scale, or flow-curve record.

GT1000 maximum pressure by meter size

Family-level maximum non-shock operating pressures at fluid temperatures through 250°F (121°C). The applicable row depends on the configured meter size and must not be selected from connection diameter alone.

Meter sizeNPT threaded maximumANSI Class 150 RF maximumPED note
2500 psig (34.5 bar)240 psig (16.5 bar)Sound Engineering Practice
6450 psig (31 bar)240 psig (16.5 bar)Sound Engineering Practice
7300 psig (20.7 bar)240 psig (16.5 bar)Sound Engineering Practice
8250 psig (17 bar)240 psig (16.5 bar)Sound Engineering Practice
9200 psig (13.8 bar)200 psig (13.8 bar)Sound Engineering Practice
10175 psig (12.1 bar)175 psig (12.1 bar)Sound Engineering Practice
12100 psig (6.9 bar)100 psig (6.9 bar)Not available for EU/EFTA use under the cited GT1000 documentation
1375 psig (5.2 bar)75 psig (5.2 bar)Not available for EU/EFTA use under the cited GT1000 documentation

Current retrofit path

Brooks positions the GT1600 Series as a configurable retrofit for GT1000 flowmeters. This is a family-level replacement path, not an exact successor assignment for 1020CZ125. A replacement must be configured to match the original tube and flow range, float, process-connection arrangement, connection size and type, seal material, scale, accuracy, alarm requirements, calibration conditions, and hazardous-location approvals.

Installation and safety notes

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median priceNot enough dataBased on archived listing records
Recorded price rangeNot enough dataLow to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

Recorded price context is shown when available. Based on 0 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instruments GT1020 Industrial Glass Tube Variable Area Flowmeter W/Alarm

Archived listings

Other Part Numbers & Aliases

1020CZ125Brooks 1020CZ125Brooks Instrument 1020CZ125