Flow Control

1250AR6081MRSVV

Brooks Instrument Sho-Rate 1250 Flowmeter

About this part

1250AR6081MRSVV is a configured Brooks Instrument Sho-Rate 1250 glass tube variable area flowmeter identifier. Stored Sonisys auction titles identify it as a Brooks flowmeter with an air range of 0 to 10,100 CCM. Brooks official 1250/1255 documentation places the 1250 family in low-flow glass tube variable area flowmeters and lists R6081 in the Model 1250 millimeter-reference capacity table with 10,100 CCM air and 235 CCM water reference capacities. Final suitability still depends on the physical unit label, tube/float assembly, scale, end-block material, valve configuration, seals, process fluid, pressure, and temperature

Unit-specific configuration
Observed configuration

Historical listing records identify this part as AIR at 0-10,100 CCM. Exact gas, range, fittings, valve configuration, and communication interface must be verified from the physical unit label.

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument
Part number1250AR6081MRSVV
Product familyConfiguration-specific
Device typeFlowmeter
Observed gasAIR
Observed full-scale range0-10,100 CCM
Configuration statusVerify from unit label
Application classLife sciences and laboratory automation
CategoryFlow Control

Specifications

Identification
Device typeSho-Rate 1250 glass tube variable area flowmeter / rotameter
Series familyBrooks Sho-Rate 1250/1255 low-flow glass tube variable area flowmeters
Configured part number1250AR6081MRSVV
Base model contextBrooks model-code documentation identifies 1250A as the 65 mm tube flowmeter base model and 1255A as the 150 mm tube flowmeter base model
Flow
Measuring principleVariable area flowmeter with tapered borosilicate glass metering tube and metering float
Observed stored auction rangeStored auction titles describe this configured part as Range at CCM of Air 0-10100
R6081 reference capacityBrooks 1250/1255 documentation lists R6081 with 10,100 CCM air and 235 CCM water in the Model 1250 millimeter reference scale capacity table
Configuration
Configured-unit ruleTube number, float material, reference scale, flow units, end-block material, connection, valve, O-ring material, and process-fluid assumptions must be verified from the specific unit and documentation
Reference conditionsBrooks 1250/1255 data sheet states reference conditions of 70 F (21.1 C) and 14.7 psia (1 bar absolute) for listed gas accuracy context
Performance
1250 family accuracyBrooks 1250/1255 data sheet lists 1250 accuracy as 5% full scale at reference conditions for listed gases
RepeatabilityBrooks 1250/1255 data sheet lists repeatability as 0.25% full scale
Pressure and temperature
Series-level pressure/temperatureBrooks 1250/1255 data sheet lists 200 psig from 33 F to 250 F / 13.8 bar from 1 C to 121 C; verify the configured unit and application before using this limit
Materials
Series-level materialsBrooks 1250/1255 data sheet lists borosilicate glass, aluminum, 316 stainless steel, clear polycarbonate, and Teflon in materials of construction
Float materialsBrooks 1250/1255 documentation lists glass, sapphire, stainless steel, Carboloy, and tantalum float material options
Seal optionsBrooks 1250/1255 data sheet lists Buna and Viton packing/O-ring options
Connections
Connection optionsBrooks 1250/1255 data sheet lists 1/8 NPT with locknuts for aluminum or stainless steel and 1/4 NPT with locknuts for stainless steel only
Valve
Valve optionsBrooks 1250/1255 data sheet lists cartridge valve options with stainless steel or brass valve materials
Maintenance
Tube assembly serviceBrooks documentation describes quick removal or installation of tube and float while the meter remains in process piping, and the data sheet describes EZ-CHANGE tube assembly interchangeability
Applications
Application domainLow-flow gas and liquid indication in laboratory, industrial, and OEM applications; exact gas/liquid use is configuration and scale dependent

Documentation Downloads

Local PDF copies

Part Photos

1 image

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records55Tracked historical listing records
Historical median price$319.99Based on archived listing records
Recorded price range$319.99 - $319.99Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $319.99 to $319.99. Based on 55 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • BROOKS 1250AR6081MRSVV Flowmeter,Range @ CCM of Air 0-10100
  • BROOKS 1250AR6081MRSVV Flowmeter,Range at CCM of Air 0-10100

Archived listings

Other Part Numbers & Aliases

1250AR6081MRSVVBrooks 1250AR6081MRSVVBrooks Instrument 1250AR6081MRSVV1250A R6081 M R S V V1250A R6081Brooks 1250A R6081