1350EN2PAHV1A8800D2L1A1CA represents a Brooks Instrument configured Sho-Rate 1350E glass tube variable-area flowmeter assembly observed with an 8800D2L1A1CA flow-controller code. Official Brooks 1350E/1355E documentation supports the Sho-Rate 50 / Model 1350E flowmeter family context, and official Brooks FC documentation supports FC 8800 flow controllers for liquid and gas flow service with variable upstream pressure. Exact tube, float, scale, service fluid, flow range, process connection, seal, material package, and controller build details remain configured-unit properties that should be verified from the physical unit label and markings
Configurations vary. Verify the exact unit before choosing a replacement.
Variable-area flow indication using a tapered borosilicate glass metering tube and float
Scale
1350 Series scale context
Brooks 1350E/1355E data-sheet context lists the 1350 Series scale length as 65 mm nominal, with R-65 mm or R-100 linear reference scale options depending on configuration
Performance
1350 Series accuracy context
Brooks 1350E/1355E data-sheet context lists 1350 Series standard accuracy as +/-10% of full scale
Repeatability context
Brooks 1350E/1355E data-sheet context lists repeatability as 0.5% full scale
Pressure and temperature
Flowmeter family rating context
Brooks 1350E/1355E documentation lists 200 psig from 33 F to 250 F / 1 C to 121 C, and 170 psig over the same temperature range when supplied under CRN certification
Construction
Flowmeter materials context
Brooks 1350E/1355E documentation lists borosilicate glass metering tubes, multiple float material options, chrome plated brass, black anodized aluminum, and 316 stainless steel end-fitting options, and configuration-specific packing and O-ring materials
Connections
Flowmeter connection context
Brooks 1350E/1355E data-sheet context lists standard horizontal female 1/8 inch NPT threaded adapters with locknuts, plus optional compression, 1/4 inch female NPT, and hose connection configurations
Controls
Flowmeter control options
Brooks 1350E/1355E documentation describes optional standard integral needle valves, NRS integral control valves, and integral flow controllers on the inlet or outlet
Flow controller
FC 8800 role
Brooks FC documentation identifies Series FC 8800 controllers as liquid and gas flow controllers for variable upstream pressure service
Controller operating principle
Brooks FC documentation describes the controller as maintaining a fixed differential pressure across an integral manual flow regulating valve by using a diaphragm-actuated internal control valve
Configuration
Configured-unit rule
Tube and float code, direct-reading scale, service fluid, flow range, valve or controller option, connection, seal, end-fitting material, side-plate material, accessory selections, and pressure certification vary by configured code and unit label
Applications
Application domain
Low-flow gas and liquid indication or local manual flow control, depending on configured tube, float, scale, controller, materials, and process conditions