Brooks Instrument Sho-Rate 1350E Variable Area Flowmeter
About this part
1350EZ122 is a configured Brooks Instrument Sho-Rate 50 / Model 1350E glass tube variable-area flowmeter identifier. Official Brooks 1350E/1355E documentation provides the family-level flowmeter construction, accuracy, pressure/temperature, connection, scale, valve, controller, installation, and maintenance context. The Z122 suffix and observed 209-134 or 213-167 material-number context should be treated as configured-unit or customer/OEM evidence unless verified from the physical unit label, scale markings, or official build documentation
Configurations vary. Verify the exact unit before choosing a replacement.
Application classIndustrial automation and process equipment
CategoryFlow Control
Specifications
Identification
Device type
Glass tube variable-area flowmeter / rotameter
Series family
Brooks Sho-Rate 1350E / 1355E family
1350E family name
Sho-Rate 50
Configured model code
1350EZ122
Function
Measuring principle
Variable area flow indication using a tapered glass metering tube and metering float
Scale
1350 series scale length
65 mm nominal
Scale options
Standard R-65 mm or R-100 linear reference scale with air or water calibration table, depending on configuration
Performance
1350 Series accuracy
Brooks 1350E/1355E data sheet lists 1350 Series standard accuracy as +/-10% full scale
1355 Series accuracy
Brooks 1350E/1355E data sheet lists 1355 Series standard accuracy as +/-5% full scale
Repeatability
Brooks 1350E/1355E data sheet lists repeatability as 0.5% full scale
Pressure and temperature
Standard pressure and temperature rating
Brooks 1350E/1355E documentation lists 200 psig from 33 F to 250 F / 1 C to 121 C
Construction
Metering tube material
Borosilicate glass
Float material options
Glass, 316 stainless steel, sapphire, Carboloy, and tantalum
End fitting material options
Chrome plated brass, black anodized aluminum, and 316 stainless steel
Connections
Standard connection
Horizontal female 1/8 inch NPT threaded adapters with locknuts for front panel mounting
Controls
Integral control options
Standard integral flow control valve, NRS integral flow control valve, and 8800/8900 integral flow controller configurations are supported by the family documentation
Installation
Orientation
Install within 6 degrees of true vertical with inlet connection at the bottom end fitting
Configuration
Configured-unit rule
Tube, float, direct-reading scale, valve or controller option, end-block material, seal material, process connection, calibrated fluid, and flow range must be verified from the specific unit label and scale markings
Observed variants
Stored auction and surplus context
Stored Sonisys auction records and external surplus/listing evidence identify 1350EZ122 as a Brooks Sho-Rate metering valve or flowmeter and associate exact-code listings with 209-134 or 213-167 material-number context
Applications
Application domain
Low-flow gas and liquid indication, purge flow service, panel-mounted rotameter applications, and configured flow-control assemblies