Flow Control

5863I

Brooks Instrument Mass Flow Meter

About this part

5863I is a Brooks Instrument 5800-series high-flow thermal mass flow meter family identifier found in stored Sonisys auction records. Official Brooks 5853/5863 documentation covers the 5863 mass flow meter platform, while stored auction records also include seller wording for configured 5863i units with 300 SLPM air and 80 SLPM air contexts. Exact gas, range, fittings, output option, pressure rating, and calibration details must be verified from the physical unit label and calibration paperwork

Unit-specific configuration
Observed configuration

Historical listing records identify this part as Air at 300 SLPM. Exact gas, range, fittings, valve configuration, and communication interface must be verified from the physical unit label.

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument
Part number5863I
Product familyConfiguration-specific
Device typeFlow Meter
Observed gasAir
Observed full-scale range300 SLPM
Configuration statusVerify from unit label
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
Device typeThermal mass flow meter for gases
Model familyBrooks Instrument Model 5863 / 5863i Series
Part identifier5863I / 5863i
Official manual boundaryBrooks 5853/5863 family documentation covers the high-flow 5800-series controller/meter platform; exact 5863i configuration must be checked from the unit label
Function
Primary functionMeasures gas mass flow and provides an electrical flow output signal
Internal measurement architectureThermal mass-flow measurement with integral electronics, configured by model code and calibration
Flow
High-flow family context5863-family listings and Brooks 5800-series context place this model in high-flow gas mass-flow service; exact full-scale range is configuration-specific
Observed variants
Stored auction gas/range combinationsStored Sonisys titles include 300 SLPM air and 80 SLPM air configured-unit contexts
Calibration
Configured-unit ruleGas calibration, full-scale range, output option, fittings, pressure rating, connector wiring, and customer-specific suffixes vary by configured model code
Electrical
Output contextBrooks 5800-series thermal mass flow meters commonly provide analog flow output; exact voltage/current option must be verified from the label and wiring documentation
Mechanical
Connection contextProcess connection size and style are configuration-specific and should be verified from the unit and Brooks documentation
Applications
Application domainHigh-flow gas mass-flow measurement in semiconductor, process, laboratory, and industrial gas systems
Compatibility
Verification boundaryDo not assume interchangeability with 5853 controllers, 5860i meters, SLA-series meters, or another configured Brooks unit without checking gas, range, fittings, output, wiring, and pressure rating

Documentation Downloads

Local PDF copies

Part Photos

6 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records6Tracked historical listing records
Historical median price$1,600.00Based on archived listing records
Recorded price range$332.50 - $1,650.00Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $641.25 to $1,650.00. Based on 6 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument 5863i Mass Flow Meter

Archived listings

Other Part Numbers & Aliases

5863IBrooks 5863IBrooks Instrument 5863I