5866A1Z1075 is a configured Brooks Instrument 5866-family pressure-control flow device observed in stored auction records as a mass flow controller. Official Brooks 5866RT documentation describes the family as a pressure controller/flowmeter that controls upstream or downstream pressure from a remote pressure transducer while also measuring mass flow through the control valve. Exact gas, range, valve behavior, seal package, fitting, pressure-transducer interface, and calibration details must be verified from the complete model code and physical label
Configurations vary. Verify the exact unit before choosing a replacement.
Brooks 5866 / 5866RT pressure controller and flowmeter family
Function
Pressure-control function
Maintains a desired upstream or downstream pressure by comparing a remote pressure transducer signal to the setpoint and modulating the integral control valve
Flow-measurement function
Measures mass flow through the control valve and provides a 0-5 V signal proportional to mass flow
Mass-flow-controller mode
The Brooks 5866RT platform can be configured as a mass flow controller for calibration or test purposes
Pressure
Control architecture
Remote pressure sensor input with adjustable integral PID control electronics and control-valve modulation
Remote pressure sensor compatibility
Suitable for pressure sensors with 0-5 V or 0-10 V output signals
Pressure-control range
100:1 when used with a remote transducer that has a 0-10 V output
Pressure response time
Less than 0.8 seconds typical for a 0-100% command step with less than 2% pressure overshoot; actual response depends on system design
Flow
Flow range
5866RT family range coverage spans 0-3 sccm to 0-30,000 sccm nitrogen equivalent; this configured unit's range must be verified from its label
Flow output signal
0-5 Vdc, 1 kOhm maximum load
Flow accuracy
+/-1.0% full scale including linearity at calibration conditions for 3-10,000 sccm nitrogen equivalent; +/-1.5% full scale for flow rates greater than 20 slpm
Controls
Pressure setpoint signal
0-5 Vdc or 0-10 Vdc command, with 5 Vdc reference output available for setpoint generation
Valve override
Electrically activated valve override is part of the 5866RT control platform
Electrical
Electrical connector
15-pin D-connector, DA-15P
Power requirement, normally closed valve
3.5 W; +15 Vdc +/-5% at 35 mA and -15 Vdc +/-5% at 180 mA
Power requirement, normally open valve
10.5 W; +/-15 Vdc +/-5% at 350 mA
Ratings
Operating temperature range
32 to 150 degrees F (0 to 65 degrees C)
Materials
Standard wetted parts
316L and 316L VAR stainless steel
Seal and valve-seat options
Configured units may use elastomer or metal seals; valve-seat and seal materials vary by configured model code
Connections
Mechanical connection options
5866RT family configurations include stainless steel compression fittings, VCO, and VCR options depending on model code
Configuration
Configured-unit rule
Gas, flow range, pressure mode, valve behavior, seal package, fitting, pressure-transducer interface, and calibration details vary by the full configured model code
Observed listing context
Stored auction titles identify the unit as BROOKS 5866A1Z1075 MASS FLOW CONTROLLER T252744; T252744 is retained as auction context, not an exact part-number alias
Documentation
Hosted family documents
Brooks 5866RT series data sheet and installation/operation manual are available as local PDF downloads