The Brooks Instrument 5866RT is a remote-transducer electronic pressure controller/flowmeter. Official Brooks documentation identifies Model 5866RT as a pressure controller that controls upstream or downstream pressure while simultaneously measuring mass flow through the control valve. Gas, full-scale flow range, pressure-transducer range, seal package, valve behavior, and fitting configuration remain unit-specific and should be verified from the physical label or build records
Configurations vary. Verify the exact unit before choosing a replacement.
Controls upstream or downstream pressure by comparing a remote pressure-transducer signal to the setpoint and modulating the integral control valve
Flow-measurement function
Measures mass flow through the control valve and provides a 0-5 Vdc signal proportional to mass flow
Mass-flow-controller mode
Can be configured as a mass flow controller for calibration or test purposes
Pressure
Control architecture
Remote pressure sensor input with adjustable integral PID control electronics and control-valve modulation
Remote pressure sensor compatibility
Suitable for pressure sensors with 0-5 Vdc or 0-10 Vdc output signals
Pressure-control range
100:1 when used with a remote transducer that has a 0-10 Vdc output
Pressure response time
Less than 0.8 seconds typical for a 0-100% command step with less than 2% pressure overshoot; actual response depends on system design
Flow
Flow range
Any range from 0-3 sccm to 0-30,000 sccm nitrogen equivalent at SEMI standard reference conditions, depending on configuration
Flow output signal
0-5 Vdc, 1 kOhm maximum load
Flow accuracy
+/-1.0% full scale including linearity at calibration conditions for 3-10,000 sccm nitrogen equivalent; +/-1.5% full scale for flow rates greater than 20 slpm
Flow repeatability
+/-0.25% of rate
Controls
Pressure setpoint signal
0-5 Vdc or 0-10 Vdc command, with 5 Vdc reference output available for setpoint generation
Valve override
Electrically activated valve override
Electrical
Electrical connector
15-pin D-connector, DA-15P
Power requirement, normally closed valve
3.5 W; +15 Vdc +/-5% at 35 mA and -15 Vdc +/-5% at 180 mA
Power requirement, normally open valve
10.5 W; +/-15 Vdc +/-5% at 350 mA
Ratings
Operating temperature range
32 to 150 degrees F (0 to 65 degrees C)
Maximum pressure
1500 psi listed on the Brooks pressure-control product category page
Pressure Equipment Directive context
Brooks data sheet lists PED 97/23/EC Sound Engineering Practice for the 5866RT platform
Materials
Wetted parts
Standard wetted parts are 316L and 316L VAR stainless steel
Valve seat options
Standard Viton fluoroelastomer or metal valve seat depending on configured model code
Seal options
External and internal seals can be fluoroelastomer or metal, with Buna-N, Teflon, or Kalrez options depending on configuration
Leak Integrity
Elastomer seal
1 x 10^-9 atm cc/sec helium maximum, inbound to outboard
Metal seal
1 x 10^-10 atm scc/sec helium maximum, inbound to outboard
Connections
Standard mechanical connections
1/8 in or 1/4 in stainless steel compression fittings
Optional mechanical connections
1/4 in VCO or VCR options; 5866RT(M) metal-sealed configuration uses 1/4 in VCR
Installation
Mounting orientation
May be installed in any position
Filter recommendation
Brooks recommends an upstream in-line filter for elastomer 5866RT installations to help prevent foreign material from entering the meter
Applications
Application domain
Upstream or downstream gas pressure control with simultaneous flow measurement, including vacuum-chamber pressure regulation, inert-gas feed control, process-vessel pressure control, and flow-related calibration or test service
Configuration
Unit-specific details
Gas calibration, full-scale flow, pressure-transducer range, valve behavior, seal package, and fittings vary by configured unit and must be verified from the physical label or build documentation
Documentation
Hosted exact model documents
Brooks 5866RT series data sheet and installation/operation manual are available as local PDF downloads