Flow Control

5964C2MAKX5KA

Brooks Instrument Model 5964 Metal-Sealed Mass Flow Controller

About this part

5964C2MAKX5KA is a configured Brooks Instrument Model 5964 metal-sealed thermal mass flow controller identifier. The official Brooks 5964/5850EM manual supports Model 5964 use in high-purity and high-vacuum gas-flow systems, with an electropolished 7 Ra flow path, enhanced-response electronics, analog signal options, and configuration-dependent process connections. Stored auction evidence associates this exact identifier with Novellus customer part 22-10519-00, but that association is retained only as observed identity context. No verified official document naming the full 5964C2MAKX5KA code is currently available, so gas calibration, full-scale range, valve configuration, connection style, I/O option, pressure rating, and interchangeability must be verified from the physical label and calibration records

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument
Part number5964C2MAKX5KA
Product familyConfiguration-specific
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
Part identifier5964C2MAKX5KA
Official model familyBrooks Instrument Model 5964 metal-sealed mass flow controller
Function
Measurement and control principleThermal mass flow sensing with an integral control valve for gas-flow measurement and regulation
Flow
Model-family flow rangeOfficial 5964/5850EM manual lists selectable full-scale ranges from 3 sccm through 30,000 sccm nitrogen equivalent, with lower flows available by factory consultation; the range of 5964C2MAKX5KA is not established by the documentation
Performance
Accuracy1% of full scale including linearity at calibration conditions; 1.5% of full scale for flow ranges above 20 slpm
Repeatability0.25% of rate
Model 5964 settling timeEnhanced-response PCB: less than 1 second to within 2% of full scale of final value for a 0-100% command step with a normally closed valve
Control range2-100% with an elastomeric valve seat or 3-100% with a metal or Teflon valve seat; installed seat must be verified
Ratings
Operating pressure boundaryManual lists 1,500 psi maximum, with 150 psi for enhanced-response configurations and 500 psi for the stainless-steel-fastener option; use the configured-unit rating
Ambient temperature limitsOperating 40-150 degrees F (5-65 degrees C); non-operating -13 to 212 degrees F (-25 to 100 degrees C)
Materials
Leak integrityInboard-to-outboard helium leak rate of 1 x 10^-10 atm cc/sec maximum
Wetted construction316L VAR stainless steel, 316L stainless steel, and high-alloy ferritic stainless steel with nickel internal and external seals
Model 5964 surface finish7 Ra, electropolished
Connections
Process connection optionsOfficial manual covers 1/4-inch tube VCR, downport C-seal, and downport W-seal configurations; the connection on 5964C2MAKX5KA must be checked physically
Electrical
Electrical connection options20-pin card-edge or 15-pin D-connector configurations are documented; the exact connector must be verified on the unit
Analog I/O options0-5 Vdc command/output or 4-20 mA command with jumper-selectable 4-20 mA or 0-20 mA output, depending on configured electronics
Configuration
Configured-unit ruleGas, calibration range, valve state and seat, process connection, electrical interface, supply requirements, pressure limit, and calibration orientation must be verified from the complete physical label and calibration documentation
Observed context
Observed customer-part associationStored auction records and an external exact-part listing associate 5964C2MAKX5KA with Novellus 22-10519-00; this is observed identity context, not an official Brooks compatibility specification

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records2Tracked historical listing records
Historical median price$151.06Based on archived listing records
Recorded price range$147.18 - $154.93Low to high recorded listing price
Local documents1PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $147.96 to $154.16. Based on 2 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks 5964C2MAKX5KA Mass Flow Controller MFC Novellus 22-10519-00 Working Spare

Archived listings

Other Part Numbers & Aliases

5964C2MAKX5KABrooks 5964C2MAKX5KABrooks Instrument 5964C2MAKX5KA