Mass Flow Controllers

MF50XA4BC3P2CAA

Brooks Instrument MF50X Thermal Mass Flow Controller

About this part

MF50XA4BC3P2CAA is a configured Brooks Instrument MF50X thermal mass flow controller for industrial gases. MF50 identifies the controller size covering 3 sccm through 30 slpm nitrogen-equivalent full-scale ranges, while X identifies the welded-sensor Mfx construction with NEMA 4X/IP66 packaging and hazardous-location approvals. The remaining suffix is configuration-specific; the calibrated gas, exact full-scale range, process connection, seal material and selected signal arrangement must be taken from the instrument nameplate or calibration record

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument MF Series (Mfx)
Part numberMF50XA4BC3P2CAA
Product familyConfiguration-specific
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryMass Flow Controllers

Specifications

Identification
ManufacturerBrooks Instrument
Series and modelMF Series, MF50X configured controller
Device functionThermal mass flow measurement and closed-loop gas flow control with an integral solenoid valve and remote setpoint input
Construction
Sensor constructionWelded, non-removable sensor assembly (Mfx construction)
EnclosureNEMA Type 4X / IP66 watertight industrial enclosure
Flow performance
Available MF50 full-scale range3 sccm to 30 slpm nitrogen equivalent at 0 °C and 101 kPa; the exact configured full scale is not established
Control range50:1
Accuracy±1% of full scale including linearity at calibrated conditions; ±1.5% of full scale for MF50 ranges above 20 slpm
Repeatability0.25% of rate
Response timeLess than 6 seconds to within 2% of full scale for a 0–100% command change
Low-flow cutoffThe control valve closes when the command is below 1% of full scale
Pressure
Maximum operating pressure1500 psig (100 bar) for the MF50 controller family
Controller differential pressure5 to 50 psid
Environmental
Ambient and gas temperature5 to 65 °C (41 to 149 °F)
Integrity
Outboard leak specification1 × 10^-9 atm·cc/s helium, excluding permeation
Electrical
Supply voltage15 to 28 VDC
Current requirement240 mA at 15 VDC; 370 mA at 28 VDC
Setpoint choices0–5 VDC or 4–20 mA; exact configured selection is not established
Flow outputs0–5 VDC plus jumper-selectable 0–20 mA or 4–20 mA output
Valve overrideElectrical input permits the control valve to be forced fully open or closed
Field wiringPluggable screw-terminal connections through a watertight cable gland or conduit fitting, depending on configuration
Approvals
Hazardous-location classificationMfx family: Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; suitable for Class III, Division 2
North American certificationUL Listed and UL Recognized under E73889; classification cited to UL 1604 and CSA C22.2 No. 213
Electromagnetic compatibilityEN 61326 under EMC Directive 89/336/EEC

Configuration-code interpretation

The published MF50X family literature establishes the base model but does not provide a position-by-position decoder for suffix A4BC3P2CAA. Calibration-dependent and option-dependent details therefore remain nameplate-controlled.

MF50Thermal mass flow controller model supporting nitrogen-equivalent full-scale ranges from 3 sccm through 30 slpm.
XMfx construction with a welded, non-removable sensor and hazardous-location enclosure.
A4BC3P2CAAFactory configuration suffix; published family literature does not establish its exact gas, range, connection, seal or signal selections.

MF50X controller signal terminals

The MF Series terminal-strip assignments applicable to the controller model are shown below. Unused terminals are omitted.

TerminalLabelFunction
TB-1/1VSUPPositive supply voltage
TB-1/2SUPCOMSupply common
TB-1/4SUPCOMSignal common
TB-1/5VSIGVoltage flow-signal output
TB-1/6ISIGCurrent flow-signal output
TB-2/2GNDChassis ground
TB-2/4VREF+5 VDC reference output
TB-2/5VORValve-override input
TB-2/7CMDCOMCommand common
TB-2/8VCMDVoltage setpoint input
TB-2/9ICMDCurrent setpoint input

Service safety

Before disconnecting an instrument that has carried toxic, pyrophoric, flammable or corrosive gas, purge it thoroughly with a dry inert gas such as nitrogen. This protects personnel and limits fire, explosion, corrosion and contamination hazards.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records2Tracked historical listing records
Historical median price$190.00Based on archived listing records
Recorded price range$180.00 - $200.00Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $182.00 to $198.00. Based on 2 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • BROOKS MF50XA4BC3P2CAA MF SERIES UNMP
  • BROOKS MF50XA4BC3P2CAA MF SERIES ( AS PICTURED) UNMP

Archived listings

Other Part Numbers & Aliases

MF50XA4BC3P2CAABrooks MF50XA4BC3P2CAABrooks Instrument MF50XA4BC3P2CAA