Flow Control

QMBC3L1B3A1A1A2AA1X7A1AA

Brooks Instrument Quantim QMB Coriolis Mass Flow Controller

About this part

QMBC3L1B3A1A1A2AA1X7A1AA is a configured Brooks Instrument Quantim QMB-series Coriolis mass flow controller identifier observed in Sonisys auction records. Official Brooks documentation identifies QMB as a legacy low-flow Coriolis meter/controller series and identifies QMBC as the controller model with an integral control valve. The complete configured suffix was not decoded in an official exact-part build sheet, so fluid, full-scale calibration, wetted materials, seal package, enclosure, approvals, connector, output, and process-connection details should be verified from the physical unit label, calibration record, or Brooks build documentation

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument
Part numberQMBC3L1B3A1A1A2AA1X7A1AA
Product familyConfiguration-specific
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
Part identifierQMBC3L1B3A1A1A2AA1X7A1AA
ManufacturerBrooks Instrument
Series familyBrooks Quantim QMB Series low-flow Coriolis mass flow meters and controllers
Model roleBrooks QMB documentation identifies QMBC as a Quantim controller with an integral control valve, distinct from QMBM meter variants without a valve
Flow
Measurement principleCoriolis mass-flow measurement with fluid density and temperature measurement context in the official QMB-series manual
QMBC size-3 family range contextOfficial QMB-series documentation lists QMBC tube size 3 controller-class liquid maximum flow of 1.00 kg/hr, nominal liquid flow of 0.78 kg/hr, and nominal gas flow of 0.214 kg/hr; exact configured calibration remains nameplate dependent
Performance
Family accuracy contextOfficial QMB-series documentation lists standard measurement accuracy context of 0.2% of rate for liquid and 0.5% of rate for gas, with accuracy limited by zero stability at low flows
Controller turndown contextOfficial QMB-series documentation lists controller turndown as 100:1 or down to the minimum measurable flow, whichever flow rate is greater
Electrical
Power contextOfficial QMB quick-start wiring diagrams show 14-27 Vdc power-source context for the Quantim device; verify wiring and I/O against the physical unit before service
Configuration
Configured-unit ruleFluid, full-scale range, process connections, wetted materials, seals, enclosure, approvals, electrical interface, valve details, and calibration vary by complete configured code and unit records
Documentation
Official document coverageThe locally hosted Brooks QMB Series installation and operation manual applies to the QMB/Quantim family but does not name or fully decode the exact QMBC3L1B3A1A1A2AA1X7A1AA configured suffix

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records3Tracked historical listing records
Historical median price$49.98Based on archived listing records
Recorded price range$24.97 - $49.98Low to high recorded listing price
Local documents1PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $29.97 to $49.98. Based on 3 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument QMBC3L1B3A1A1A2AA1X7A1AA Legacy Mass Flow Controller

Archived listings

Other Part Numbers & Aliases

QMBC3L1B3A1A1A2AA1X7A1AABrooks QMBC3L1B3A1A1A2AA1X7A1AABrooks Instrument QMBC3L1B3A1A1A2AA1X7A1AA