Flow Control

QMBS4L1A3D1A1CM2C1A1E

Brooks Instrument Quantim QMBS4 Modbus Coriolis Mass Flow Sensor

About this part

Brooks Instrument QMBS4L1A3D1A1CM2C1A1E is a Quantim QmBS4 Coriolis mass flow sensor with Modbus RS-485 output. Its supported model-code prefix specifies the large tube size, liquid as the primary fluid type, no pressure transducer, no valve, 0.5% liquid-flow accuracy with a 316L sensor tube, and a NEMA 4X/IP65 hazardous-area enclosure. Published QmBS4 performance is 13.5 kg/hr nominal and 27 kg/hr maximum for liquids. The supplied identifier omits positions required by the published full ordering-code format; its pressure rating, process connection, seals, certifications, filter, and OEM option are therefore not asserted

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument Quantim QmBS
Part numberQMBS4L1A3D1A1CM2C1A1E
Product familyConfiguration-specific
Device typeCoriolis mass flow sensor
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Product familyQuantim QmBS
Base modelQMBS flow sensor with Modbus RS-485 output
Measurement
Measuring principleDirect Coriolis mass-flow measurement
Configured Options
Tube size4 — large sensor
Primary fluid typeLiquid; switching to gas is permitted after rezeroing
Pressure transducerNone
ValveNone; measurement-only sensor
Specified mass-flow accuracy±0.5% of rate or ±[(zero stability ÷ flow rate) × 100]% of rate, whichever is greater
Enclosure and area classificationNEMA 4X/IP65; Class I, Division 2/Zone 2
Surface finishStandard, 32 Ra
Sensor tube material316L stainless steel
Tube Size 4 Performance
Nominal liquid flow13.5 kg/hr (29.77 lb/hr)
Maximum liquid flow27 kg/hr (59.54 lb/hr)
Typical gas flow3.640 kg/hr; 50,350 sccm on air at stated reference conditions
Zero stability0.0040 kg/hr (0.0088 lb/hr) with stainless-steel sensor tube
Documented QmBS Family
Mass-flow repeatability±0.05% of rate or ±[0.5 × (zero stability ÷ flow rate) × 100]% of rate, whichever is greater
Density range0–0.3 and 0.5–2.0 g/cm³; consult Brooks for 0.3–0.5 g/cm³
Density accuracy and repeatabilityAccuracy ±0.005 g/cm³; repeatability ±0.002 g/cm³
Ambient and process temperature0–65°C (32–149°F); device-temperature accuracy ±0.5°C (±1.0°F)
Materials
Documented wetted materials316/316L stainless steel; the configured sensor-tube code specifies 316L stainless steel
HousingPolyurethane-painted aluminum and stainless steel

What Does QMBS4L1A3D1A1CM2C1A1E Mean?

The published June 2006 ordering table supports the leading fields shown below. The remaining compact suffix cannot be aligned conservatively with every required field.

SegmentFieldInterpretation
QMBSBase modelQuantim flow sensor with Modbus RS-485 output
4Tube sizeLarge sensor; 13.5 kg/hr nominal liquid flow
LPrimary fluid typeLiquid; liquid/gas switching requires rezeroing
1Pressure transducerNo transducer
AValve typeNo valve
3AccuracyOptional 0.5% of rate for liquid measurement with stainless-steel sensor tube
DEnclosure and area classificationNEMA 4X/IP65; Class I, Division 2/Zone 2
1Surface finishStandard, 32 Ra
ASensor tube material316L stainless steel
1CM2C1A1ERemaining suffixNot positionally complete under the published full model-code revision; no further exact options are asserted

Tube Size 4 Flow Capability

Flow limits depend on the process fluid and stated reference conditions.

MediumDocumented flowReference basis
Liquid13.5 kg/hr nominal; 27 kg/hr maximumWater at reference conditions; volumetric values assume density of 1 g/cm³
Gas3.640 kg/hr; 50,350 sccm typicalAir at 70°F, 500 psia inlet, and approximately 1 bar pressure drop

Compatibility and Replacement

Brooks classifies the QMB series as legacy and directs customers to the current Quantim QMC family.

LifecycleQMB is listed as a legacy Brooks Instrument series; the manufacturer’s upgrade table maps Quantim QMB to Quantim QMC.
Compatibility boundaryBrooks describes QMC as form-, fit-, and function-compatible with second-generation QMB models. Do not assert plug-and-play electrical or protocol compatibility for this QMBS remote sensor: QmBS documentation specifies Modbus and a circular sensor connection, while current QMC documentation specifies RS485 S-Protocol and different configured I/O arrangements.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$499.00Based on archived listing records
Recorded price range$499.00 - $499.00Low to high recorded listing price
Local documents4PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $499.00 to $499.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • BROOKS INSTRUMENT QUANTIM QMBS4L1A3D1A1CM2C1A1E PRECISION MASS FLOW 500PSI/35BAR

Archived listings

Other Part Numbers & Aliases

QMBS4L1A3D1A1CM2C1A1EBrooks QMBS4L1A3D1A1CM2C1A1EBrooks Instrument QMBS4L1A3D1A1CM2C1A1E