Flow Control

SLA6850V1EGB1A2A1

Brooks Instrument Metal-Sealed Mass Flow Controller

About this part

Brooks SLA6850V1EGB1A2A1 is a configured SLA6850 closed-loop gas mass flow controller from the Delta Class SLA6800 metal-sealed family. SLA6850 performance limits are documented at model level, while the calibrated gas, full-scale range, process connection, electrical interface, valve seat, and calibration set must be confirmed from the individual instrument’s nameplate, calibration record, or original order

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument Delta Class SLA6800 Series
Part numberSLA6850V1EGB1A2A1
Product familySLA6850 Series
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Base modelSLA6850
SeriesDelta Class SLA6800 Series
Device functionClosed-loop thermal mass flow controller for gases
Flow
Documented SLA6850 full-scale rangeAny range from 0–3 sccm through 0–30,000 sccm nitrogen equivalent; the configured full-scale range is calibration/order-specific
Control range50:1 with an elastomeric valve seat or 33:1 with a metal valve seat; the seat fitted to this configured identifier is not established
Pressure differential5–50 psid maximum range for SLA6850; actual minimum and maximum pressure drop depend on gas and full-scale flow
Performance
Accuracy±1.0% of rate including linearity from 20% to 100% full scale; ±0.2% of full scale below 20% full scale
Repeatability±0.20% of rate
Settling timeLess than 800 ms to within ±2% of full scale of final value for a 0–100% step, per SEMI E17-91
Temperature sensitivityZero: less than 0.075% of full scale per °C; span: less than ±1% of full scale shift over 10–50°C
Documented long-term driftLess than 0.2% per year
Ratings
Maximum operating pressure1500 psig; 150 psig (10.35 bar) maximum is recommended for optimal performance
Ambient temperatureOperating: 0–60°C (32–140°F); non-operating: −25–100°C (−13–212°F)
Maximum fluid temperature0–65°C (32–149°F)
Leak integrityInboard-to-outboard helium leak rate not greater than 1 × 10^-10 atm-scc/s
Construction
Materials316L vacuum-arc-remelt stainless steel, 316L stainless steel, and high-alloy ferritic stainless steel
Seals and valve seatNickel external/internal seals and standard 316L stainless-steel valve seat are documented; an elastomeric valve-seat option is also documented, so the configured seat must be verified
Internal wetted surface finish32 Ra for the SLA6800 Series
Connections
Documented process-connection options1/4-inch male VCR, CS seal, or C seal; the configured connection is not established by the available exact-code evidence
Electrical
Documented interface optionsAnalog I/O using a 15-pin male D-connector or DeviceNet using a 5-pin male Micro-Connector; exact configured interface not established
Analog signals0–5 Vdc setpoint and flow signals, valve override, and calibration-select input
Power supplyAnalog option: +15 Vdc ±5%; DeviceNet option: nominal 11–25 Vdc
Calibration
Calibration storageUp to 10 selectable calibration and flow-range sets; each ordered set can include gas calibration, PID settings, valve-performance data, and calibration conditions

What Does SLA6850V1EGB1A2A1 Mean?

The published model designation establishes the instrument family and controller function. The complete configured suffix requires the instrument record or manufacturer decoding software.

SegmentFieldInterpretation
SLA6850Brooks modelDelta Class SLA6800 Series metal-sealed gas mass flow controller; documented model range extends from 3 to 30,000 sccm nitrogen equivalent.
V1EGB1A2A1Configured option suffixA Brooks Product Data Code suffix representing device options. A complete public selection table for this legacy suffix was not located; confirm its fields from the nameplate, original order, or Brooks BEST device information.

Configured Gas and Range

Gas and flow range are calibration attributes rather than one universal specification for every unit carrying this code.

Calibration capacityThe SLA6850 platform can store as many as 10 ordered calibration sets.
Required unit evidenceUse the nameplate, calibration table, original order, or a verified device readout to establish gas, full-scale range, operating pressures, and active calibration.

Legacy Status and Replacement

Brooks includes SLA6850 in its obsolete mass flow controller and meter list. A replacement must be selected against the unit’s calibrated gas and range, pressure conditions, process connection, valve configuration, electrical interface, and dimensional requirements; no universal drop-in successor should be inferred from the base model alone.

Documentation Downloads

Local PDF copies

Part Photos

3 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$1,995.00Based on archived listing records
Recorded price range$1,995.00 - $1,995.00Low to high recorded listing price
Local documents2PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $1,995.00 to $1,995.00. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument SLA6850V1EGB1A2A1 Mass Flow Controller

Archived listings

Other Part Numbers & Aliases

SLA6850V1EGB1A2A1Brooks SLA6850V1EGB1A2A1Brooks Instrument SLA6850V1EGB1A2A1