About this part

SLAMF60S1BCA0K2A3 is a Brooks Instrument SLAMf Series digital thermal mass flow meter for gas measurement in harsh environments. Its ordering code specifies RS485 communication, a 1/4-inch tube-compression connection, PTFE O-ring, sensor-only construction, 4–20 mA analog I/O through a 1/2-inch NPT female conduit entry, nominal 24 Vdc power, standard response, and UL Listed Division 2/Zone 2 certification. The calibrated gas, exact full-scale flow, pressure build, and revision require the unit nameplate or manufacturer calibration record

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument SLAMf Series
Part numberSLAMF60S1BCA0K2A3
Product familyConfiguration-specific
Device typeFlow Meter
Configuration statusConfiguration varies
Application classIndustrial automation and process equipment
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Product familySLAMf Series
Base modelSLAMf60
FunctionDigital thermal mass flow meter; measure-only sensor with no control valve
Package / finishCode MF — standard elastomer series
Flow
Measuring principleThermal mass flow measurement for gases
Body sizeCode 0
Documented flow-range envelope0.003–50 slpm, N2 equivalent; the exact calibrated full-scale range is not encoded by this identifier
SLAMf50/60 standard accuracyISO 17025-certified devices: ±0.6% of set point from 20–100% F.S. and ±0.12% F.S. below 20% F.S.; including calibration-system uncertainty: ±0.9% of set point and ±0.18% F.S., respectively. The identifier does not establish the calibration certificate supplied with the unit
SLAMf50/60 repeatability and reproducibility0.20% of set point
Mechanical
Process connectionCode 1B — 1/4-inch tube compression, without the optional integral filter
O-ring materialCode C — PTFE
Valve seatCode A — none; sensor-only configuration
Valve typeCode 0 — none; sensor-only configuration
Communications
Digital communicationCode S — RS485 using Brooks enhanced S-Protocol
Analog I/OCode K — 4–20 mA / 4–20 mA with 1/2-inch NPT female conduit entry; the setpoint channel described for controllers is not a flow-control function on this meter
Electrical
Nominal power inputCode 2 — 24 Vdc
RS485-family supply range+13.5 to +27 Vdc
Maximum power consumption2 W for an RS485 unit without a valve
Configuration
Output enhancementCode A — standard response; no Biotech Performance or Premium package encoded
Environmental
Ingress protectionIP66 hardened enclosure
Operating temperature−14 to 65 °C (7 to 149 °F)
Pressure
SLAMf60 model envelopeStandard maximum operating pressure is 1500 psi / 103 bar; an optional configuration supports up to 4500 psi / 310 bar with meter flow limited to 10 lpm. The identifier does not establish which pressure build was supplied
Certification
Certification codeCode 3 — Division 2 / Zone 2 UL Listed
UL Listed hazardous-location coverageClass I, Division 2, Groups A, B, C and D; Class I, Zone 2, IIC T4; Class II, Zone 22, IP66
Diagnostics
Service portRS485 through a 2.5 mm diagnostic jack

What Does SLAMF60S1BCA0K2A3 Mean?

The identifier follows the Brooks SLAMf ordering-code positions. Each configured segment below is defined by the July 2026 manufacturer data sheet.

SegmentFieldInterpretation
SLABase modelBrooks SLA platform
MFPackage / finishStandard elastomer series
6FunctionMass flow meter
0Body size3 ccm–50 lpm N2-equivalent model envelope
SDigital I/O communicationRS485; select applicable analog I/O
1BMechanical connection1/4-inch tube compression
CO-ring materialPTFE
AValve seatNone; sensor only
0Valve typeNone; sensor only
KAnalog I/O communication4–20 mA / 4–20 mA, 1/2-inch NPT female conduit
2Power-supply input24 Vdc
AOutput enhancementStandard response
3CertificationDivision 2 / Zone 2 UL Listed

Configuration Details Not Encoded by the Identifier

These values remain unit-specific and must come from the nameplate, calibration certificate, or an exact manufacturer record.

Calibrated gasNot encoded
Exact full-scale flowNot encoded; only the body-size envelope is established
Pressure buildStandard versus optional high-pressure construction is not encoded
Revision levelRev A or Rev B is not established by this identifier alone
Stored gas pagesCalibration records are required to identify the gases programmed into the unit

Hazardous-Area Installation Warnings

The manufacturer’s UL Listed installation requirements apply to certification code 3.

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$299.99Based on archived listing records
Recorded price range$299.99 - $299.99Low to high recorded listing price
Local documents4PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $299.99 to $299.99. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • BROOKS SLAMF60S1BCA0K2A3 FE/FT-5500-03 MASS FLOW T262548

Archived listings

Other Part Numbers & Aliases

SLAMF60S1BCA0K2A3