Flow Control

BD1DA1FB2AA1B2

Brooks Instrument 5851S Smart Mass Flow Controller —

About this part

BD1DA1FB2AA1B2 identifies a configured Brooks Instrument 5851S Smart thermal mass flow controller. Its ordering code specifies 3/8-inch tube-compression fittings, Viton seals and valve seat, a normally closed valve, RS-232 communication at 19,200 baud, digital setpoint control with digital and 4–20 mA flow output, standard response, one standard calibration, 24 VDC power, and ATEX Zone 2 classification. The exact calibration gas and full-scale value are calibration-record attributes and are not encoded in this identifier

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument 5800-S Smart Series
Part numberBD1DA1FB2AA1B2
Product family5850S
Device typeMass Flow Controller
Configuration statusConfiguration varies
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
ManufacturerBrooks Instrument
Series5800-S Smart Series
Base model5851S
Complete model code5851S/BD1DA1FB2AA1B2
Product
Instrument typeSmart thermal mass flow controller for gases
Flow
Full-scale selection band20–100 ln/min nitrogen-equivalent; the exact selected full-scale value is not encoded
Reference conditions0 °C and 1013.25 mbar
Standard accuracy±0.7% of rate plus ±0.2% of full scale at calibration conditions
Repeatability±0.25% of rate
Rangeability50:1 within specified accuracy
Controllability100:1 total operating range
Long-term stabilityLess than ±0.5% of rate per year
Configured Process Interface
Process connections3/8-inch tube-compression fittings
O-ring and valve-seat materialViton fluoroelastomer
Configured Valve
Valve typeNormally closed
Configured Electrical Interface
Setpoint inputDigital communication
Flow outputsDigital communication and 4–20 mA analog output
Serial interfaceRS-232 at 19,200 baud
Interconnection cableNo cable supplied by the ordering-code selection
Power input+24 VDC
Electrical
Normal power consumption+24 VDC ±10% at 140 mA
Power consumption with valve override active+24 VDC at 370 mA
Connector15-pin male D-type connector with gold-plated contacts
Alarm outputNPN TTL open collector; 30 VDC and 25 mA maximum
Configured Performance
Response selectionStandard response; approximately 1-second nominal settling and flow-output response
Configured Calibration
Calibration selectionOne standard calibration included; gas and exact full-scale value are not encoded
Configured Certification
Area classificationATEX Zone 2, KEMA 03ATEX1433 X, II 3 G EEx nA II T4
Operating Limits
Ambient and process-gas temperature0–70 °C
5851S pressure rating100 bar maximum
Performance
External leak integrity1 × 10^-9 mbar·L/s helium
Warm-upLess than 10 minutes for 1% full-scale accuracy; 45 minutes for performance within specifications
Dimensions
Connection dimension A148 mm without filters or 184 mm with filters for the configured 3/8-inch tube-compression connections

What Does BD1DA1FB2AA1B2 Mean?

Brooks ordering literature divides the identifier into the following configured selections.

SegmentFieldInterpretation
BDBase model and flow band5851S mass flow controller; selectable full scale from 20 to 100 ln/min nitrogen-equivalent
1DMechanical connection3/8-inch tube-compression fittings
AO-ring and valve-seat materialViton fluoroelastomer
1Valve typeNormally closed valve for the 5850S/5851S series
FElectrical input/outputDigital communication input; digital communication and 4–20 mA output
B2Communication and baud rateRS-232 at 19,200 baud
AInterconnection cableNo cable
AEnhancementStandard-response configuration
1CalibrationOne standard calibration included
BPower input+24 VDC standard selection
2Area classificationCertified for use in ATEX Zone 2

Configured Connector Signals

Signals relevant to the configured 24 VDC, RS-232, 4–20 mA interface are listed below.

PinSignalFunction
3TTL open-collector alarmNPN alarm output, 30 VDC and 25 mA maximum
44–20 mA flow outputConfigured analog flow signal
5+24 VDC supplyPositive power input
9Power-supply commonSupply and serial common reference
10Flow-output commonAnalog flow-signal return
12Valve overrideFloating for normal control; ≥5 VDC commands open and ≤0 VDC commands closed
14RS-232 RxDSerial receive
15RS-232 TxDSerial transmit

Calibration-Specific Data

The ordering code confirms a standard calibration but does not encode the calibration gas or exact full-scale flow value. These values must be taken from the instrument’s calibration label or certificate.

Installation and Safety Notes

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records1Tracked historical listing records
Historical median price$59.99Based on archived listing records
Recorded price range$59.99 - $59.99Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $59.99 to $59.99. Based on 1 archived listing record; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument SMART MASS FLOW Oxygen Controller 5851S BD1DA1FB2AA1B2

Archived listings

Other Part Numbers & Aliases

BD1DA1FB2AA1B25851S/BD1DA1FB2AA1B2