Flow Control

GF125X-109845

Brooks Instrument GF125 Series Metal-Sealed Mass Flow Controller

About this part

GF125X-109845 is a configured Brooks Instrument GF125/GF100-family metal-sealed thermal mass flow controller for semiconductor, MOCVD, thin-film, and high-purity gas delivery. Official Brooks GF100/GF120/GF125 documentation covers the platform, family-level performance context, wetted materials, communication families, MultiFlo support, and installation guidance, but no verified official one-part specification for GF125X-109845 is currently available Stored Sonisys auction history associates this exact configured identifier with N2 1000 SCCM listing context; verify gas, full-scale range, valve state, fitting package, communication option, and any customer or OEM marking from the physical unit label before reuse

Unit-specific configuration
Observed configuration

Historical listing records identify this part as N2 at 1000 SCCM. Exact gas, range, fittings, valve configuration, and communication interface must be verified from the physical unit label.

Configurations vary. Verify the exact unit before choosing a replacement.

No archived photo available

Key Facts

ManufacturerBrooks Instrument
Part numberGF125X-109845
Product familyGF100 Series
Device typeMass Flow Controller
Observed gasN2
Observed full-scale range1000 SCCM
Configuration statusVerify from unit label
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
Part identifierGF125X-109845
Device typeMetal-sealed thermal mass flow controller
Series familyBrooks GF100 / GF120 / GF125 metal-sealed mass flow controller and meter family
Applications
Application domainSemiconductor, MOCVD, thin-film, and high-purity process gas flow control applications requiring an all-metal flow path
Performance
Family accuracy contextBrooks GF100/GF120/GF125 documentation lists +/-1% of set point above 35-100% and +/-0.35% full scale over 2-35% based on factory N2 calibration for applicable analog and DeviceNet configurations
Family repeatability contextBrooks GF100/GF120/GF125 documentation lists repeatability and reproducibility of +/-0.15% of set point from 5-100% and +/-0.015% full scale from 2-5%
Family settling-time contextBrooks GF100/GF120/GF125 documentation lists normally closed valve settling-time bins from 300 ms to less than 700 ms across documented flow bins, depending on configuration
GF125 pressure-transient contextBrooks GF100/GF120/GF125 documentation describes GF125 as pressure transient insensitive; applicability to this configured unit should be confirmed from the full model code and label
Materials
Wetted path standardBrooks GF100/GF120/GF125 documentation describes SEMI F20 HP compliant wetted materials
Wetted materials contextBrooks GF100/GF120/GF125 documentation lists wetted material context including 316L VIM/VAR, Hastelloy C-22, 316L stainless steel, 304 stainless steel, KM-45, and PCTFE on optional zero leak-by valve configurations
Leak integrity
External leak integrityBrooks GF100/GF120/GF125 data-sheet table lists external leak integrity of 1 x 10^-10 atm cc/sec helium
Controls
Communication interfacesBrooks documentation provides Analog/RS-485, DeviceNet, RS485 L-Protocol, and EtherCAT context for the GF100 family; the actual interface depends on the configured electronics option
Flow
Gas/range programmabilityMultiFlo gas and range configurability is documented for supported GF100-family devices
Ratings
Operating temperature contextBrooks GF100/GF120/GF125 documentation lists a 10 C to 50 C operating temperature range for documented family configurations
Configuration
Configured-unit ruleGas, full-scale flow range, valve or meter configuration, fitting package, electrical connector, communication protocol, display, surface finish, seal package, and customer/OEM options vary by full configured model code
Observed configuration
Stored auction gas/range combinationsStored exact listing evidence includes N2 1000 SCCM for GF125X-109845; this is observed auction context, not an official model-wide specification
Stored listing observationsStored exact auction evidence identifies GF125X-109845 as a Brooks Instrument mass flow controller; use this only as observed identity context

Documentation Downloads

Local PDF copies

Part Photos

0 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records2Tracked historical listing records
Historical median price$1,507.75Based on archived listing records
Recorded price range$1,204.25 - $1,811.24Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $1,264.95 to $1,750.54. Based on 2 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks Instrument GF125X-109845 Mass Flow Controller 0190-86737 Lot of 2 New
  • Brooks GF125X-109845 Mass Flow Controller MFC 1000 SCCM N2 New Surplus

Archived listings

Other Part Numbers & Aliases

GF125X-109845Brooks GF125X-109845Brooks Instrument GF125X-109845