Flow Control

SLA7950S

Brooks Instrument SLA7900 Series Metal-Sealed Mass Flow Controller

About this part

SLA7950S is a Brooks Instrument SLA7900 Series high-purity, metal-sealed thermal mass flow controller or meter configuration. Brooks documentation identifies SLA7950S as an analog-I/O SLA7950/SLA7960 form factor with 9-pin or 15-pin D-connector options, 0-5 V setpoint and flow signals, 13.5 to 27 VDC analog power, high leak integrity metal seals, and 0-3 sccm to 0-50 slpm N2-equivalent flow-range capability depending on the configured unit

Unit-specific configuration
Observed configuration

Historical listing records identify this part as N2O. Exact gas, range, fittings, valve configuration, and communication interface must be verified from the physical unit label.

Configurations vary. Verify the exact unit before choosing a replacement.

Key Facts

ManufacturerBrooks Instrument
Part numberSLA7950S
Product familySLA7900 Series
Device typeThermal Mass Flow Device
Observed gasN2O
Configuration statusVerify from unit label
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control

Specifications

Identification
Device typeHigh-purity metal-sealed thermal mass flow controller or meter
Series familySLA7900 Series
Related documented modelsBrooks Models SLA7950 and SLA7960 mass flow controllers and meters
SLA7950S interface identitySLA7950S is documented as the analog-I/O model with 9-pin or 15-pin D-connector configurations
Configuration
Configured-unit ruleGas, full-scale range, communication interface, valve state, and fittings vary by configured model code
Applications
Application domainAdvanced gas handling systems requiring high-purity or ultra-high-purity metal-sealed flow measurement and control
Flow
Flow range capabilityAny range from 0-3 sccm to 0-50 slpm N2 equivalent for SLA7950/SLA7960 models
Turndown100:1 for full-scale ranges from 1 to 50 slpm; 50:1 for full-scale ranges below 1 slpm
Performance
Accuracy+/-1.0% of rate including linearity from 20% to 100% full scale; +/-0.2% of full scale below 20% full scale
Repeatability+/-0.20% of rate
Settling timeLess than 1 second for step changes above 5% full scale
Long-term driftLess than 0.2% per year
Mounting attitude sensitivity0.2% of full-scale maximum deviation after rezeroing
Pressure
Maximum operating pressure1500 psig maximum; 150 psig and below recommended for best performance
Differential pressure range5 to 50 psid, with broader ranges depending on customer conditions
Leak integrity
Inboard-to-outboard leak rateLess than 1 x 10^-10 atm scc/sec helium maximum
Valve leak-byLess than 0.5% full scale
Materials
Wetted materials316L Vacuum Arc Remelt stainless steel, 316L stainless steel, high-alloy ferritic stainless steel, nickel seals, and 17-7PH stainless steel valve seat
Wetted surface finishElectropolished to 5 Ra
Connections
Process connections1/4 inch male VCR, CS seal, C seal, and W seal configurations
Controls
Analog I/O0-5 V setpoint and flow signals with separate valve-override signal
Analog connectors9-pin or 15-pin male D-connector options
RS-485 option15-pin D-connector RS-485 option using Brooks S-Protocol based on HART
DeviceNet family optionSLA7950D and related SLA7000/SLA7900 DeviceNet variants use a 5-pin Micro-Connector and ODVA mass-flow-controller profile support
Electrical
Analog power supply13.5 to 27 VDC, 15 VDC nominal
Analog or RS-485 power requirement with valve4.2 W typical, 4.6 W maximum
DeviceNet power requirement with valve6.3 W typical, 6.9 W maximum for DeviceNet family variants
Environment
Operating ambient temperature0 C to 65 C (32 F to 149 F)
Non-operating ambient temperature-25 C to 100 C (-13 F to 212 F)
Cleanliness
Particulate specificationZero particles per cubic foot greater than 0.1 microns under process conditions; less than 4 particles per cubic foot greater than 0.02 microns under process conditions
Functionality
Calibration storageDevice can store 10 selectable calibration and flow ranges
Observed variants
Stored auction gas/range combinationsN2O (12), NF3 15 SLM (11), SIH4 300 SCCM (4), AR 3 SLM (4), N2O 15 SLM (3), 30 SCCM (2), AR 3000 SCCM (1), HE 5 SLM (1)

Documentation Downloads

Local PDF copies

Part Photos

17 images

Historical archive images for identification, labels, connectors, and condition reference, not current inventory.

Historical Listings & Prices

Historical listing data, not a current offer
Archive records42Tracked historical listing records
Historical median price$212.87Based on archived listing records
Recorded price range$99.00 - $1,260.10Low to high recorded listing price
Local documents3PDF copies available from Sonisys
Recorded price context

The typical recorded price range is $180.59 to $380.90. Based on 42 archived listing records; not a current offer, appraisal, or confirmed sale price.

View archived listing titles
  • Brooks SLA7950S MFC Mass Flow Controller 15 SLPM N2O
  • [10388]BROOKS SLA7950S _ GAS:NF3 _ 15 SLPM _MFC/Fedex
  • [10392]BROOKS SLA7950S _ GAS:N20 _ 2000 SCCM_ MFC/Fedex
  • [10389]BROOKS SLA7950S _ GAS:N20 _ 2000 SCCM_ MFC/Fedex
  • BROOKS 1-888-554-FLOW USED SLA7950S NF3 15 SLPM DELTA CLASS SMART MFC-I-78=2M32
  • BROOKS USED SLA7950S SiH4 300SCCM DELTA CLASS SMART MASS FLOW MFC-I-76=2M32

Archived listings

Other Part Numbers & Aliases

SLA7950SSLA 7950SSLA7950SLA7900Brooks SLA7950SBrooks Instrument SLA7950SDelta Class SLA7950SSLA7950S MFCSLA7950S MFM