Brooks Instrument SLA7900 DeviceNet Metal-Sealed Mass Flow Controller
About this part
SLA7950D is a Brooks Instrument SLA7900 Series metal-sealed digital thermal mass flow controller or meter model associated with DeviceNet digital I/O configurations. Brooks-authored SLA7900 documentation identifies SLA7950D DeviceNet variants with VCR and downport connection drawings, while gas, full-scale range, valve state, fitting package, and calibration remain configured-unit properties. Stored Sonisys auction evidence for this exact model includes Hydrogen 200 SCCM, AR 200 SCCM, AR 2 SLM, AR 3 SLM, AR 50 SCCM, SiH4 2 SLM, NF3 1.5 SLM, and WF6 30 SCCM observed configurations
Unit-specific configuration
Observed configuration
Historical listing records identify this part as HYDROGEN at 200 SCCM. Exact gas, range, fittings, valve configuration, and communication interface must be verified from the physical unit label.
Configurations vary. Verify the exact unit before choosing a replacement.
Application classSemiconductor/high-purity gas delivery
CategoryFlow Control
Specifications
Identification
Device type
High-purity metal-sealed DeviceNet thermal mass flow controller or meter
Series family
Brooks SLA7900 Series; Brooks-authored family documentation covers Models SLA7950 and SLA7960 mass flow controllers and meters
DeviceNet model identity
SLA7950D is documented as the DeviceNet digital-I/O SLA7950 model variant, with VCR and downport connection layouts shown in the SLA7900 installation manual
Configuration
Configured-unit rule
Gas, full-scale flow range, process connections, valve behavior, DeviceNet setup, and calibration options vary by configured model code and unit label
Applications
Application domain
Advanced high-purity and ultra-high-purity gas handling systems, including semiconductor process gas flow measurement and control
Flow
Series flow range capability
Brooks-authored SLA7900 data-sheet context lists any range from 0-3 sccm to 0-50 slpm N2 equivalent for SLA7950/SLA7960 models
Observed stored auction configurations
Hydrogen 200 SCCM (2), AR 200 SCCM (1), AR 2 SLM (1), AR 3 SLM (1), AR 50 SCCM (1), SiH4 2 SLM (1), NF3 1.5 SLM (1), WF6 30 SCCM (1)
Performance
Family accuracy context
Brooks-authored SLA7900 data-sheet context lists +/-1.0% of rate including linearity from 20% to 100% full scale and +/-0.2% full scale below 20% full scale
Family repeatability and response context
Brooks-authored SLA7900 data-sheet context lists +/-0.20% of rate repeatability and less than 1 second settling time for step changes above 5% full scale
Pressure
Family pressure context
Brooks-authored SLA7900 data-sheet context lists 1500 psig maximum operating pressure, with 150 psig and below recommended for best performance
Leak integrity
Family metal-seal context
Brooks-authored SLA7900 data-sheet context lists all-metal seals and inboard-to-outboard leak integrity less than 1 x 10^-10 atm scc/sec helium maximum
Materials
Family wetted-material context
Brooks-authored SLA7900 data-sheet context identifies 316L VAR stainless steel, 316L stainless steel, high-alloy ferritic stainless steel, nickel seals, and 17-7PH stainless steel valve-seat material for documented family configurations
Family wetted-surface context
Brooks-authored SLA7900 data-sheet context describes wetted surfaces as electropolished to 5 Ra for documented family configurations
Connections
Process connections
Brooks-authored SLA7900 documentation shows SLA7950D DeviceNet variants with VCR and downport seal connection configurations; exact fitting package should be verified from the unit label and body
Controls
DeviceNet interface
SLA7950D family variants use DeviceNet digital communication; Brooks DeviceNet support material lists SLA7000 Series MFC documentation and SLA7800/SLA7900 EDS file context
DeviceNet connector context
SLA7000/SLA7900 DeviceNet variants are documented with a 5-pin Micro-Connector and ODVA mass-flow-controller profile support
Electrical
DeviceNet power requirement with valve
Brooks-authored SLA7900 data-sheet context lists 6.3 W typical and 6.9 W maximum for DeviceNet family variants with valve
Environment
Family operating ambient context
Brooks-authored SLA7900 data-sheet context lists operating ambient temperature from 0 C to 65 C and non-operating ambient temperature from -25 C to 100 C
Cleanliness
Family particulate context
Brooks-authored SLA7900 data-sheet context lists zero particles per cubic foot greater than 0.1 microns under process conditions and less than 4 particles per cubic foot greater than 0.02 microns under process conditions
Functionality
Calibration storage
Brooks-authored SLA7900 family context describes storage and pre-programming of up to 10 gas calibrations or ranges on a single device